Latest offer from Huntron

Near Field Signature Analyzers -
Huntron Access® 2 NFSA

Automated RF Near Field Measurements

Combining the Huntron Access Prober, Huntron Workstation Software and the new Test Evolution (TEV) Non-Contact Near Field Signature Huntron Access 2 NFSA Analysis (NFSA) Probe sets the standard for Near Field Signature Analysis (NFSA). The combination of Huntron Prober and TEV RF Probe allows accurate positioning and measurement of Virtual Test Points (VTPs). This provides the repeatability to measure VTP's from 30MHZ to 3GHZ.
The Huntron Access 2 NFSA can handle PCAs up to 15.3" x 18" (38.9cm x 45.7cm) and has four slot levels for vertical PCA positioning. The Access 2 NFSA can handle the taller components on PCAs with 4" (10cm) of clearance.

Test Evolution (TEV) NFSA Probe

Near Field Signal Measurements Both systems use the Test Evolution (TEV) NFSA Probe that is used to for fault determination in high frequency electronic circuits. The test frequency range is 30MHz to 3GHZ. The TEV NFSA Probe is an integrated monopole antenna, receiver and spectrum analyzer connected through a USB port. Central to this test system is the ability to place the TEV NFSA Probe at a repeatable position and distance from the Virtual Test Point. The Huntron Access Prober delivers this repeatability with +/- 20um placement accuracy on the XY plane and 200um resolution on the Z axis.

A more technical “white paper” description of the Huntron Access NFSA system can be downloaded using this link (presented at AutoTestCon 2008):
Case Study of Near Field Signature Analysis (NFSA)

Huntron Access and Access 2 NFSA features

For more information on Near Field Signature Analysis from Huntron and Test Evolution Corp., download the Near Field Signature Analysis datasheet (registration required) or contact Huntron directly.

Specifications

All specifications apply to the Huntron Access NFSA Prober and Access 2 NFSA Prober unless otherwise noted. To view a more complete specification list, download Additional Information.

Access Prober Hardware Specifications
Maximum Board-Under-Test Size
Access 2 NFSA Prober 22" x 23" (56cm x 58cm)
Maximum Board-Probing Area
Access 2 NFSAProber 15.3" x 18" (38.9cm x 45.7cm)
Maximum Allowable Component Height on Board Under Test
Access 2 NFSA Prober 4" (10cm)
Prober Dimensions
Access 2 NFSA Prober 36" W x 15.7" H x 29" D (91.44cm W x 39.88cm H x 73.66cm D)
Accuracy 0.0007874" (±20 microns)
Minimum
Resolution
0.0003937" (10 microns)
Maximum Z Travel
Access 2 NFSA Prober 4.2" (10.6cm)
Power Requirements
Line Voltage
Power
115VAC or 230VAC
100W
GENERAL
Vision System 640px x 480px color images
PC Interface USB
Certifications CE and ETL listed
Warranty 1 year limited
NFSA Probe by TEV Specifications
Frequency range 30MHz - 3GHZ
Frequency Resolution Bandwidth 300Hz, 600Hz, 1.2KHz, 2.4KHz
Attenuator Ranges 0-60dB in 10dB steps
Sensitivity @ 1mm Offset 0dB attenuator range, 300Hz RBW at 10x averaging
PC Interface USB