Near Field Signature Analyzers
Automated RF Near Field Measurements
Combining the Huntron Access Prober, Huntron Workstation Software and the new Test Evolution (TEV) Non-Contact Near Field Signature
Analysis (NFSA) Probe sets the standard for Near Field Signature Analysis (NFSA). The combination of Huntron Prober and TEV RF Probe
allows accurate positioning and measurement of Virtual Test Points (VTPs). This provides the repeatability to measure VTP's from 30MHZ to 3GHZ.
The Huntron Access 2 NFSA can handle PCAs up
to 15.3" x 18" (38.9cm x 45.7cm) and has four slot levels for vertical PCA positioning.
The Access 2 NFSA can handle the taller components on PCAs with 4" (10cm) of clearance.
Test Evolution (TEV) NFSA Probe
Both systems use the Test Evolution (TEV) NFSA Probe that is used to for fault determination in high frequency electronic circuits. The test frequency range is
30MHz to 3GHZ. The TEV NFSA Probe is an integrated monopole antenna, receiver and spectrum analyzer connected through a USB port. Central to this test system is the ability
to place the TEV NFSA Probe at a repeatable position and distance from the Virtual Test Point. The Huntron Access Prober delivers this repeatability with +/- 20um placement accuracy on the
XY plane and 200um resolution on the Z axis.
A more technical “white paper” description of the Huntron Access NFSA system can be downloaded using this link (presented at AutoTestCon 2008):
Case Study of Near Field Signature Analysis (NFSA)
Near Field Signature Software Features
- Integrated NFSA Probe by TEV
- Precise, repeatable placement of NFSA Probe over VTR
- 30MHz to 3GHz test frequency range
- Placement accuracy of +/- 20um
- Integrated control and storage of Near Field Signatures in Huntron Workstation NFSA software
Specifications
- Huntron Access NFSA Part Numbers
- Access 2 NFSA Prober - Part Number 99-0406
- Access 2 Prober (NFSA Probe ready) - Part Number 99-0413
- TEV NFSA RF Probe head for Access 2 NFSA- Part Number 98-0533
All specifications apply to the Huntron Access NFSA Prober and Access 2 NFSA Prober unless otherwise noted. To view a more complete specification list, download Additional Information.
| Access Prober Hardware Specifications | |
| Maximum Board-Under-Test Size | |
| Access 2 NFSA Prober | 22" x 23" (56cm x 58cm) |
| Maximum Board-Probing Area | |
| Access 2 NFSAProber | 15.3" x 18" (38.9cm x 45.7cm) |
| Maximum Allowable Component Height on Board Under Test | |
| Access 2 NFSA Prober | 4" (10cm) |
| Prober Dimensions | |
| Access 2 NFSA Prober | 36" W x 15.7" H x 29" D (91.44cm W x 39.88cm H x 73.66cm D) |
| Accuracy | 0.0007874" (±20 microns) |
| Minimum Resolution |
0.0003937" (10 microns) |
| Maximum Z Travel | |
| Access 2 NFSA Prober | 4.2" (10.6cm) |
| Power Requirements | |
| Line Voltage Power |
115VAC or 230VAC 100W |
| GENERAL | |
| Vision System | 640px x 480px color images |
| PC Interface | USB |
| Certifications | CE and ETL listed |
| Warranty | 1 year limited |
| NFSA Probe by TEV Specifications | |
| Frequency range | 30MHz - 3GHZ |
| Frequency Resolution Bandwidth | 300Hz, 600Hz, 1.2KHz, 2.4KHz |
| Attenuator Ranges | 0-60dB in 10dB steps |
| Sensitivity @ 1mm Offset | 0dB attenuator range, 300Hz RBW at 10x averaging |
| PC Interface | USB |