Huntron Technical Support recommends that you do not use the “Prober Diagnostics” which can be selected under the Tools/Maintenance menu. You will run the risk of corrupting the internal motor control settings programmed into your Huntron Prober. This issue will be fixed in the next software release. Please contact Huntron technical Suppport with any questions.
Huntron Workstation version 4 Product page: Link to Product page for Huntron Workstation 4 outlining basic features and specifications.
Huntron Workstation Software Tutorial: Link to a tutorial guiding you through basic use of the Huntron Workstation version 4. Download size is 4.5MB.
Huntron Tracker Model 30 and Workstation Software Tutorial: Link to a tutorial specifically written for use with the Tracker Model 30, Scanner IIi and Huntron Workstation. Download size is 2.3MB.
Huntron Workstation CAD Import Tutorial: Link to a tutorial guiding you through using CAD data for test creation in Huntron Workstation version 4. Download size is 3.9MB.
Huntron Workstation Software Report Form: Form for reporting an issue with Huntron Workstation or for offering suggestions for software features. This report goes directly to Huntron Technical Support.
Huntron Workstation Sample Test: This is a sample database which can be opened in Huntron Workstation 4.0. It includes a full test database, signatures, CAD data, alignment images and a board image. Download and unzip this file and save it to your “My Documents/Huntron/Boards” folder. Start Huntron Workstation and select File/Open. Browse to the location of the saved file and open it. Download size is 10.6MB.
Download the latest software using the link below. To install, close Huntron Workstation. Unzip the workstation2881.zip file to a folder and then optionally burn the folder contents to a CD. Install the software by double clicking on the default.htm file in the folder or on the CD. Verify the install by running Huntron Workstation and selecting About Huntron Workstation from the Help menu to view the version number.
System Requirements for Workstation 4.1 This link jumps to the Workstation Software page System Requirements section.
Note: The install preparation and installation may take several minutes. Please be patient.
Note: CAD users should uninstall CAMCAD and install the version in the CAD Tools folder of the install.
Note: Huntron Workstation 4.1 runs under Microsoft Windows Vista, except for ProTracks with parallel port interface (CE or older versions). USB upgrades are available by contacting Huntron.
Note: Huntron Workstation 4.1 requires activation codes to run. The activation codes that were supplied with version 4.0 still work with 4.1.
Huntron Workstation 4.1.2881: Install CD for production release 4.1.2881; November 29, 2007 (230MB download)
Update Summary:
New Sensoray 2250 Driver Software
Sensoray 2250 Frame Grabber Aspect Ratio
Sensoray X11 Frame failure Retry
Prober IIC and IIIc Issues
Scan List File name displayed on status Bar
Fixed Component Scan Continuous Stop On Failed
Alt mode for Trackers
Troublesheet Report fixes
Prober Timeout fix
Several Exception Error Fixes
Buttons Dialog Help
Troublesheet Report sorting and pass/fail
Store ASCII Pin Level
Zoom Signature
Several Exception Error Fixes
Support for Access USB, Access USB w/ Tracker, Access 2 USB, Access 2 USB w/ Tracker
Support for Tracker Model 30, Scanner II Model 30S, Scanner Model 31S
Download the latest software patch using the link below. To install, close Huntron Workstation then unzip and execute the .MSP file. Verify the patch installation by starting Huntron Workstation and selecting About Huntron Workstation from the Help menu to view the version number. Note: The patch preparation and installation may take several minutes. Please be patient.
Huntron Workstation Patch 2678: Patch for
production release 4.1.2538; May 7, 2007 (14MB download); Important Note:
Maintenance requirements apply for this release. If your maintenance expired before May 2, 2007, it will need to be renewed before this patch can be installed.
Contact Huntron to renew your maintenance or if you have any questions.
New features:
- Live camera tab for using the Optilia video microscope or other video sources
- Sort Components/Nets by location and CAD Probes
- Group Edit for making changes on multiple pins and ranges of
multiple components
- Net Edit for making changes on multiple pins and ranges of
multiple nets
- Sync Pin/Range from signatures and Troublesheet tabs
- Get Pin Signatures to get hardware signatures of all ranges of a
pin
- Pin/Range mode for signatures setting in options
- Replace Pin Signatures to replace all of the signatures of a pin
with the hardware signatures
- Check and uncheck References for sequence scans
- Image Tab File Open remembers last file opened
- MultiSIP package for accessing scanner common pins in SIP order
(useful for Prober with Scanner systems)
- Delete Previous Scan Yes/No/Cancel
- Added Scan Pin and signature display to Remote Control
- Reset window panes to defaults
- Optional loading of previous board file
- Updated CAD control
- Changed file locations to support Windows limited users
Addressed issues in the following areas:
- CAD syncing
- Signature Zoom
- Teach Height
- Auto Store ASCII
- Database Repair
- Troublesheet
- Range editing
- Tester pane
- Scan Results Indication
Huntron Prober DLL: Users of version 4.0.2314 that have a Prober IIc or Prober IIIc should download this DLL file and save it to the Program Files\ Huntron Workstation folder. It fixes an issue with the Z axis home position in the middle and bottom prober slots.
Huntron Workstation patch 2314: Patch
for production release 4.0.2257; May 8, 2006 (12MB download); Note: Install
patch 2257 first if you currently have version 4.0.2237
Issues resolved (bold indicates fix location):
- Support for TrackerPXI Options/Hardware
- Added Sequence Scan List feature Scan Dialog
- Group Copy/Paste/Cut/Delete of Tree items Tree
- Allow Package/Number of pins component changes Tree/Component
- Command line parameters for Board file, Sequence, Component/Net
- Install for All Users or Single User Registry modification
- Updated version of Router Solutions CAMCAD (for CAD import licensed users;
see update listed below)
- Manual selection on Help menu Help
- Manual PDF file installed in Documents folder
- Support for COM5 serial port Options/Hardware
- Offset tab Reset button Prober/Offset
- Get Signature and Real-time on Troublesheet passed and removed
components Signatures/Troublesheet
- Get Signature and Real-time Z home
- Convert bottom side sequences correctly Convert
- Warning message at hardware connection before Prober goes home Workstation
startup
- Offset Z down positioning Prober/Offset
- Height warning to select pin before Sequence Down Prober/Teach Height
Huntron Workstation patch 2257: Patch
for production release 4.0.2237; March 8, 2006 (5.2MB download); Note: Install
patch 2237 first if you currently have version 4.0.2231
Issues resolved (bold indicates fix location):
- Using USB to Serial Converter locks computer after Prober moves.
- Prober III does not move correctly. During long diagonal moves. Prober
- Clicking Rescan while it is scanning causes two scans to be going on at the
same time. Disable the button during scanning. Scan
- Scans Tab DateTime Right Click Column Menu Delete All with Current .Sequence
menu items cause a Missing error.
- Software Activation error if Windows Regional Settings set to French. Activation
- Import Message box shows codes when starting HAF Assist.
- Camera offset warns of invalid offsets even when the offset is set correctly. Offset
tab
- ProTrack Diagnostics Loop Calc cannot write files w/o Admin Rights. Write
files to My Documents\Huntron\Hardware folder. Diagnostics
Huntron Workstation patch 2237: Patch
for production release 4.0.2231; Feb. 17, 2006 (630KB download)
Fixes (bold indicates fix location):
- Import Coordinates of Probes not imported correctly. Import
- Import Fiducials not working as alignment points. Import
- Options Default signature color appears to be white on fresh install. Options
- Offset Tab- If new probe position is back and left of previous position the
probe moves to the old position. Prober
- Buttons- Button causes errors with invalid file attached. List available file
types in drop down and only allow those types. ONLY ALLOW ICO, BMP, GIF AND JPG
FILES. Also updated Program and File Browse dialogs. Tree
Listed below are updates for supporting software packages used by Huntron
Workstation 4.0. To install, download the file, unzip and run the setup file.
Updated CAMCAD Pro for users of Huntron
Workstation 4.0 only : Full install of CAMCAD Pro (49MB download)
Version 4.1.2538
Feature Summary (bold indicates location):
- Optional Remote Control feature(Contact Huntron to Purchase) Activation
Code
- Support for NI Switch Executive and Geotest switch cards Tools/Options/Hardware
- Auto Align feature for Probers(Contact Huntron for Activation Code) Prober/Align
- Optional CAD feature for importing CC files directly (Contact Huntron to
Purchase) File/Import
- Reprobe mode for conformal coated boards Signature/Scan
- Opens without reference Deviation 1001 and Area 10001 to move to top on
troublesheet Signature/Troublesheet
- Added Serial Number, Operator, Passed/Failed to top of troublesheet View/Reports/Troublesheet
- Tester Pane improvements Tester
- Many other enhancements
Issues
Fixed Summary (bold indicates location):
- Faster Loading of databases with CAD data Startup
- Tree multiple selection limit issue Tree Grids
- Range Set All issues Tree/Range Grid
- Signature Zoom double click and SigAssist to right click menu Signature/Troublesheet
- SIP package relay numbers set incorrectly Tree/Pin
- Multiple Reference Compare Depth issues Signature/Scan
- Inconsistencies in scrolling signatures Signature/Troublesheet
- Sync CAD issues Image/CAD
- Footswitch issues Signature/Scan
- Prober IIc and Prober IIIc Slot issues Prober
- Many other fixes